Short answer. ASTM E1996 Level E identifies an impact test with a wood missile traveling at 80 ft/s (about 24 m/s), versus 50 ft/s (about 15 m/s) for Level D. Hurricane Solution documents that level for its HS-1500 assembly. The speed is that of the missile fired during the test.
Level E helps you judge the evidence behind a screen that protects an exposed window wall. During a hurricane, wind-borne debris can strike an opening. The impact test puts the system through a defined condition, so its performance can be compared against the criteria in the standard.
Hurricane Solution has installed certified hurricane protection in Mexico since 2008. A hurricane fabric screen is a removable textile barrier fastened over an opening to limit wind, rain, and debris. An opening is any gap in the wall, such as a window, a door, or a window wall. When you evaluate protection for a property in Playa del Carmen, identify every opening and the installation configuration proposed for each one.
In This Article
- What the missile speed represents.
- How Level D and Level E differ.
- How the test relates to the system approval.
- What to verify at your property.
What Does ASTM E1996 Level E Measure?
ASTM E1996 Level E specifies an impact condition using a wood missile. The HS-1500 spec sheet documents a roughly 9-lb piece of lumber fired at 80 ft/s (about 24 m/s), versus 50 ft/s (about 15 m/s) for Level D. Speed is what lets you compare the impact test at each level. To see the configuration that was tested, review the system documents and the corresponding test report.
The ASTM E1996-09 specification sets performance requirements for wind-borne debris. The ASTM E1886 test method describes impacts followed by cycles of pressure differential. Pressure differential is the difference in air pressure between the inside and the outside of a building during a storm. The scope of any additional water testing should be confirmed in the applicable report.
How Does Level E Compare With Level D?
Level E uses a higher impact speed for a wood missile of comparable mass. Impact energy rises with the square of velocity. Using the nominal values Hurricane Solution publishes, the ratio is (80 ÷ 50)² = 2.56. That ratio describes the missile's energy at the same mass. Choosing a system for a property also means reviewing the fasteners and the installation.
| Criterion | Level D | Level E |
|---|---|---|
| Missile speed (ft/s) | 50 | 80 |
| Approximate speed (m/s) | 15 | 24 |
| Relative energy at the same mass | 1 | 2.56 |
How Do You Connect the Test to the System Approval?
The test describes how one configuration was evaluated. A Notice of Acceptance (NOA) is the product approval issued by Miami-Dade County. Hurricane Solution's HS-1500 system is rated for Category 5 hurricanes, with a Miami-Dade NOA and ASTM E1996-09 Level E certification. Check the drawings in the approval file to confirm which screen and anchoring system it covers. An architect, engineer, or insurer can look up the Miami-Dade approval file.
What matters for your window wall is that the whole assembly keeps working as a barrier under the tested conditions. Ask for the report or test reference that applies to the assembly being offered. Hurricane Solution's technical library shows which evidence applies to the fabric itself and which covers the complete screen-and-anchor assembly.
What Does Full Building-Envelope Protection Cover?
The full building envelope means every opening in the structure is protected. Internal pressurization happens when wind gets in through a broken opening and pushes the walls and roof outward. A complete review covers side entrances, service doors, and window walls, not just the front elevation that gets most of the attention.
If you could do only one thing, ask that the test and the approval be tied to the system that would cover each opening in your property. In a home, verify the substrate before approving the fastening method. In a hotel, bring in maintenance to review access points and screen deployment as part of storm prep.
If a quote mentions Level E only in its header, ask that it identify the assembly in the bill of materials and include the report reference. That lets you check the same configuration against the property's drawings. If the scope changes during design, have the technical lead re-verify the match before any screens are fabricated.
Hypothetical Example: A Home in Playa del Carmen
Picture a home with 200 m² (about 2,150 sq ft) of built area and 40 m² (about 430 sq ft) of glazed openings. For reference, a house that size typically has 30 to 50 m² of openings. Hurricane fabric protection systems are custom-engineered based on high-velocity wind-load calculations, opening spans, mounting substrates, and motorization requirements. Contact our engineering team directly for a precise project calculation. The quote is confirmed after a free technical assessment; to request one, message us on WhatsApp.
If the project includes window walls next to a terrace, measure their width and height separately and mark where the anchors would go. A site survey can flag an opening that is hard to reach or a substrate that needs extra review. That information helps plan the installation and define the scope of protection.
When Should You Consider Another System?
If you don't have staff or a local contact who can deploy the screens, compare systems the property can operate with its own resources. It also helps to separate storm protection from permanent functions such as security, heat control, or sound insulation. Removable screens are chosen to cover openings when hurricane protection is needed.
How Do You Decide?
- Make a list of all openings and access points.
- Ask for impact evidence for the assembly being offered.
- Compare the configuration in the report and the approval with the actual substrate.
- Agree with whoever operates the property on how each screen will be installed.
In Summary
- Level E describes a more demanding impact condition than Level D.
- The test speed refers to the missile.
- The test and the approval document different aspects of the system.
- Hurricane Solution installs certified hurricane fabric screens in Mexico and publishes the evidence for the HS-1500.
- Evaluate coverage of every opening and your capacity to deploy.
To define the right system and scope for your property, request a free technical assessment with Hurricane Solution.
Frequently Asked Questions
What does ASTM E1996 Level E mean for my window wall?
Level E identifies an impact criterion using a wood missile at 80 ft/s (about 24 m/s), versus 50 ft/s (about 15 m/s) for Level D. For your window wall, verify that the evidence matches the assembly being offered and that the anchors are installed on the substrate specified in the documentation.
Does the impact result describe how any installation will perform?
The result applies to the tested assembly and the test conditions. To use it as a reference for your property, compare the screen, anchors, geometry, and substrate against the system documents. Any difference in the wall or the configuration needs technical review before installation.
How is the cost of Hurricane Solution's residential protection calculated?
Hurricane fabric protection systems are custom-engineered based on high-velocity wind-load calculations, opening spans, mounting substrates, and motorization requirements. Contact our engineering team directly for a precise project calculation. Measure the windows and doors you want covered to estimate the opening area. The quote is confirmed after a free technical assessment, and hotel and commercial projects are also quoted during that assessment. To request a quote, message us on WhatsApp.
Why does it matter to cover side doors too?
Side doors are among the openings that can be left exposed during a storm. If an opening fails, wind can get inside and push on the walls and roof. Include them in the opening survey so the scope of protection reflects the whole property.